With a DSS MUX, a new RS485 line is created on top of one of the three communication buses (A, B or C). This creates the ability to connect an additional 15 DSS devices. DSS MUX also has the ability to feed voltage to its underlying DSS nodes.
Note that some recommendations and restrictions exist for using multiple DSS MUX on the same communication bus. For more information, we welcome you to get in touch with us.
Specification
Voltage Nominal 12/24 VDC (11-30 VDC)
Maximum effect Max. 1W or 42mA at 24VDC. Normally 30mA
Power supply of subunits Feeding of sub-devices is done with 10-30 VDC (max. 300 mA) (power supplied by the input voltage)
Measure 85 x 40 x 20 mm & 120 x 70 x 30mm (plastic housing)
Weight 33 g
Environmental classification II
Operating temperature -10 ͦ C – +40 ͦ C, 0-95% air dampness
Storage temperature -10 ͦ C – +50 ͦ C, 0-95% air dampness
RS485 1 x RS485-port (to overlaying devices), 1 x RS485 port 1 x RS485 port (to underlying devices).
Input Inga
Output Inga
Alarm Classification 3/4 (SSF-1014)
CE EN-61000-6-3 (resident.), EN-61000-6-2 (indust.)
RoHS Complies the RoHS directive
Tampering Optical tamper protection
Indication 6 LED:s which indicates communication (RT / TX) to overlaying line, communication (RT / TX) with underlying line and internal status.
Max. 15 DSS-modules..